Main Control Panel
CLEAR WATER TREATMENT
SEDIMENT WATER TREATMENT
Data Trend
Displaying
Select period to
Recent data 1 hour | 3 hours | 6 hours | 12 hours | 24 hours
Logs & Alarms
Displaying 1 to 0 of 0 items
Date/Time Type TAG Description
User Management
Username Name Level Status Last Logged In Action
Back

OZONE MIXING TANK NO.1

MIXING TANK NO.1
RECIRCULATE PUMP 01
RECIRCULATE PUMP 02
SETTING
Normal Circulation Speed(%)
Down1 Circulation Speed(%)
Down2 Circulation Speed(%)
TRANSFER PUMP 01
TRANSFER PUMP 02
TRANSFER PUMP 03
TRANSFER PUMP 04
STORAGE TANK NO.1
BACKWASH PUMP 01
BACKWASH PUMP 02
CARBON FILTER TANK NO.1
INLET VALVE
SERVICE VALVE
BW. INLET VALVE
BW. OUTLET VALVE
RINSE VALVE
COMMAND
ENABLE
SETTING
BACKWASH TIME SP(MIN)
COUNT TIME (MIN)
FILTRATE TIME SP(MIN)
COUNT TIME (MIN)
RINSE TIME SP(MIN)
COUNT TIME (MIN)
CARBON FILTER TANK NO.2
INLET VALVE
SERVICE VALVE
BW. INLET VALVE
BW. OUTLET VALVE
RINSE VALVE
COMMAND
ENABLE
SETTING
BACKWASH TIME SP(MIN)
COUNT TIME (MIN)
FILTRATE TIME SP(MIN)
COUNT TIME (MIN)
RINSE TIME SP(MIN)
COUNT TIME (MIN)
CARBON FILTER TANK NO.3
INLET VALVE
SERVICE VALVE
BW. INLET VALVE
BW. OUTLET VALVE
RINSE VALVE
COMMAND
ENABLE
SETTING
BACKWASH TIME SP(MIN)
COUNT TIME (MIN)
FILTRATE TIME SP(MIN)
COUNT TIME (MIN)
RINSE TIME SP(MIN)
COUNT TIME (MIN)
CARBON FILTER TANK NO.4
INLET VALVE
SERVICE VALVE
BW. INLET VALVE
BW. OUTLET VALVE
RINSE VALVE
COMMAND
ENABLE
SETTING
BACKWASH TIME SP(MIN)
COUNT TIME (MIN)
FILTRATE TIME SP(MIN)
COUNT TIME (MIN)
RINSE TIME SP(MIN)
COUNT TIME (MIN)
INSTRUMENT SETUP
INLET DISSOLVE OZONE (NO.1)
Min
Max
Level H
Level HH
Level L
Level LL
MIXING TANK NO.1 LEVEL
Min
Max
Compensate
Measurement LV
Level H
Level HH
Level L
Level LL
OUTLET DISSOLVE OZONE (NO.2)
Min
Max
Level H
Level HH
Level L
Level LL
OUTLET CHLORINE
Min
Max
Level H
Level HH
Level L
Level LL
OUTLET FLOW
Min
Max
Level H
Level HH
Level L
Level LL
STORAGE TANK LEVEL
Min
Max
Level H
Level HH
Level L
Level LL
FLOW TOTALIZATION
MIXING TANK#1 FLOW
EQUIPMENT RUN HOUR
RECIRCULATE PUMP 01
RECIRCULATE PUMP 02
TRANSFER PUMP 01
TRANSFER PUMP 02
TRANSFER PUMP 03
TRANSFER PUMP 04
BACKWASH PUMP 01
BACKWASH PUMP 02
Back

OZONE MIXING TANK NO.2

MIXING TANK NO.2
RECIRCULATE PUMP 03
RECIRCULATE PUMP 04
SETTING
Normal Circulation Speed(%)
Down1 Circulation Speed(%)
Down2 Circulation Speed(%)
TRANSFER PUMP 05
TRANSFER PUMP 06
STORAGE TANK NO.2
BACKWASH PUMP 03
BACKWASH PUMP 04
SUMP TANK NO.1
SUPPLY PUMP 01
SUPPLY PUMP 02
CARBON FILTER TANK NO.5
INLET VALVE
SERVICE VALVE
BW. INLET VALVE
BW. OUTLET VALVE
RINSE VALVE
COMMAND
ENABLE
SETTING
BACKWASH TIME SP(MIN)
COUNT TIME (MIN)
FILTRATE TIME SP(MIN)
COUNT TIME (MIN)
RINSE TIME SP(MIN)
COUNT TIME (MIN)
INSTRUMENT SETUP
INLET DISSOLVE OZONE (NO.3)
Min
Max
Level H
Level HH
Level L
Level LL
MIXING TANK NO.2 LEVEL
Min
Max
Compensate
Measurement LV
Level H
Level HH
Level L
Level LL
OUTLET DISSOLVE OZONE (NO.4)
Min
Max
Level H
Level HH
Level L
Level LL
OUTLET CHLORINE
Min
Max
Level H
Level HH
Level L
Level LL
OUTLET FLOW
Min
Max
Level H
Level HH
Level L
Level LL
STORAGE TANK LEVEL
Min
Max
Level H
Level HH
Level L
Level LL
FLOW TOTALIZATION
MIXING TANK#2 FLOW
EQUIPMENT RUN HOUR
RECIRCULATE PUMP 03
RECIRCULATE PUMP 04
TRANSFER PUMP 05
TRANSFER PUMP 06
SUPPLY PUMP 01
SUPPLY PUMP 02
BACKWASH PUMP 03
BACKWASH PUMP 04
Back

OZONE GENERATOR

OZONE CONTROL PARAMETER
OZONE CONTROL MODE
DO3 INTERLOCK FOR MIXING#2
CONTROL SETPOINT1 (x100 g03/hr)
CONTROL SETPOINT2 (x100 g03/hr)
MODULE 1 STATUS
RUNNING STATUS
OXYGEN INLET FLOW OZM1 (LPM)
OXYGEN INLET PRESSURE OZM1 (mbar)
MAX SETPOINT (x100 g03/hr)
RUN SETPOINT (x100 g03/hr)
MIN SETPOINT (x100 g03/hr)
MODULE 2 STATUS
RUNNING STATUS
OXYGEN INLET FLOW OZM2 (LPM)
OXYGEN INLET PRESSURE OZM2 (mbar)
MAX SETPOINT (x100 g03/hr)
RUN SETPOINT (x100 g03/hr)
MIN SETPOINT (x100 g03/hr)
ALARM LIST
COOLING WATER OVER HEAT
CURRENT BELOW STD OZM1
MAIN BOARD FAULT OZM1
INVERTER OVER HEAT OZM1
AC DC CONVERTER OVER HEAT OZM1
CURRENT ABOVE STD OZM1
DOORS OPEN OZM1 OR OZM2
MAIN PHASE ERROR
OZONE OVER LOAD OZM1
EMERGENCY BUTTON WAS PRESSED
HV TRANS OVER HEAT OZM1
WATER CHILLER NO.1 OVER LOAD
OZONE RUN BUT NO COOLING WATER
OZONE1 RUN BUT NO OXYGEN
PUMP01 OVERLOAD
PUMP2 OVERLOAD
OZONE LEAK DETECTOR WARNING
OZONE LEAK DETECTOR ABNORMAL
POWER REGULATOR ERROR OZM1
OZONE POWER WARNING OZM1
OZONE POWER ABNORMAL OZM1
OZONE POWER WARNING OZM2
OZONE POWER ABNORMAL OZM2
CURRENT BELOW STD OZM2
M MAIN BOARD FAULT OZM2
M INVERTER OVER HEAT OZM2
AC DC CONVERTER OVER HEAT OZM2
CURRENT ABOVE STD OZM2
DOORS OPEN MAIN
OZONE OVER LOAD OZM2
HV TRANS OVER HEAT OZM2
WATER CHILLER NO.2 OVER LOAD
OZONE2 RUN BUT NO OXYGEN
POWER REGULATOR ERROR OZM2